Information Name: | Centrifugal fan models |
Published: | 2015-05-29 |
Validity: | 90 |
Specifications: | Complete |
Quantity: | 9999.00 |
Price Description: | |
Detailed Product Description: | In the form of a centrifugal fan model centrifugal fan from the motor side, the vane wheel rotates clockwise, known as D-blower to "right", said; counterclockwise rotation of the impeller, known as L-blower to "left". Export position of the fan to the outlet angle to the cabinet said. 4-72 fan NO2.8-7A were made at the factory one kind of type, the use of units in accordance with the requirements to install into the desired position, should pay attention when ordering. NO2.8A outlet position adjustment range 0 through 255 degrees, the interval is 45 degrees. NO3.2-7A outlet position adjustment range is from 0 through 255 degrees, one chamber is 22.5 degrees. NO08-14C / D type outlet position adjustment range 0 through 225 degrees, 45 degrees apart. NO16,20B outlet made from a fixed position are three: 0 degrees, 90 degrees, 180 degrees, and can not be adjusted. Fan drive methods are A, C, D three. 4-72 series fan of. NO2.8-7 using A-type transmission, NO8-14 using C, D drive shaft. 4-72 series fan fan structure in NO2.8-7A main distribution Direct motor consists of impeller, housing, air inlet and other units. NO8-20 addition to the above section, there are transmission parts and so on. 1) impeller from the 10 after dipping airfoil blade, curved front plate and the plate after the plate components. With a steel plate, and by the static and dynamic balance correction, air pregnant can be a good, high efficiency, smooth operation. 2) Housing made of two different types. NO2.8-14 cabinet made whole, can not open, NO16-20 casing made of three open, except along the equatorial plane is divided into two halves, the upper half is further divided into two halves along a vertical centerline with bolt edge joint. 3) air inlet formed integrally mounted on the fan side, parallel to the axial cross-section shape of the curve, the gas can into the impeller along the species, and minor damage. 4) transmission parts from the shaft, bearing housing, bearings, pulleys or coupling components. |
Admin>>>
You are the 13902 visitor
Copyright © GuangDong ICP No. 10089450, Central air-conditioning Co., Ltd. Shandong Han River All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 13902 visitor
Copyright © GuangDong ICP No. 10089450, Central air-conditioning Co., Ltd. Shandong Han River All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility